Backflow testing that keeps you compliant and your water safe
Backflow preventers protect the public water supply from contamination. Most water providers require them to be tested regularly by a certified tester, and the paperwork has to be right.
The test takes minutes. Missing the deadline can take your water service.
Test results are documented in the format your provider asks for.What a backflow preventer does
Water in your plumbing is supposed to flow one way, from the public main into your building. Under certain conditions, such as a sudden pressure drop from a water main break or firefighting, or pressure in your system exceeding the supply pressure, water can reverse direction. That reversal, called backflow, can pull water from irrigation systems, boilers, fire sprinkler lines or commercial equipment back into the drinking water supply.
A backflow prevention assembly is a mechanical device with check valves and, in some designs, a relief valve that stops reverse flow. Because these devices rely on springs, seals and moving parts, they can wear out or become fouled. Regular testing confirms that each check valve holds and each relief valve opens at the correct pressure.
Water providers and local codes commonly require testing when an assembly is installed, after repairs and at regular intervals, often annually. Testing must be done by a certified backflow tester using calibrated test equipment, and results are reported to the water provider.
When backflow testing is needed
Testing is usually triggered by a requirement, but these situations also call for it.
A notice from your water provider
Many providers send annual reminders with a deadline. Missing it can lead to follow-up notices and, in some areas, interruption of service.
A new assembly was installed
New backflow preventers are typically tested at installation to confirm they work before they are relied on.
Irrigation system start-up
Lawn sprinkler systems often have backflow preventers that should be checked when the system is turned back on in spring.
Visible leaks or discharge
Water dripping or discharging from a reduced pressure zone assembly's relief port can indicate a fouled or failing check valve.
After a repair or winter damage
Assemblies that froze, cracked or had parts replaced need to be tested before being returned to service.
Commercial or multifamily property
Buildings with boilers, fire sprinklers, commercial kitchens or process equipment commonly have multiple assemblies that each need testing.
How a backflow test is performed
Locate and identify the assembly
We record the assembly type, make, model, size and serial number, which are required on most test reports.
Connect calibrated test equipment
A differential pressure test kit is connected to the assembly's test cocks, following the procedure for that assembly type.
Test each check and relief valve
The tester verifies the pressure drop across each check valve and, on RPZ assemblies, the relief valve opening point.
Record the results
Readings are recorded, and the assembly either passes or the specific failure is noted along with the likely cause.
Repair and retest if needed
If an assembly fails, we quote the repair, typically a rebuild of seals and springs, and retest it after the work is complete.
RPZ, double check and vacuum breakers compared
Different hazards call for different assemblies. A reduced pressure zone assembly, often called an RPZ, has two independent check valves with a relief valve between them. If either check fails or pressure conditions reverse, the relief valve opens and discharges water to prevent backflow. RPZs are used where the potential contaminant could be a health hazard, such as boiler chemicals or certain commercial processes. Because they discharge water when they detect a problem, they must be installed where that water can drain safely.
A double check valve assembly uses two check valves without a relief valve and is used for lower hazard applications, including many fire sprinkler systems. A pressure vacuum breaker, common on residential irrigation, protects against back-siphonage and must be installed above the highest sprinkler head. Each type has a specific test procedure, and the tester must follow it exactly. The requirement for which type is needed on your property comes from your water provider and local plumbing code.
If your assembly fails
A failed test is common, especially on older assemblies or after winter freezing. Most failures are corrected by cleaning and replacing internal seals, springs and check discs, followed by a retest. Full replacement is only needed when the body is damaged or parts are unavailable.
Preparing for a backflow test
A backflow test is usually straightforward, but a little preparation helps it go smoothly. The tester needs access to the assembly and its test cocks, so clear away vegetation, stored items or snow around outdoor assemblies. Assemblies in vaults may require the lid to be opened and any standing water removed before testing.
During the test, water to the assembly may be shut off briefly. For businesses, it helps to schedule testing at a time when a short interruption will not affect operations. For irrigation systems, testing is often done when the system is being activated for the season.
It is helpful to have any previous test reports and the notice from your water provider available. These documents list the assembly's make, model, size and serial number and identify the reporting requirements. If the assembly has been replaced or repaired since the last test, note the changes.
After testing, the results are documented on the form required by your provider. If the assembly passes, the report is submitted or provided to you for submission. If it fails, repairs are quoted and scheduled, and a retest is performed after the work to complete compliance.
Backflow compliance mistakes
These oversights often lead to notices or failed tests.
Missing the testing deadline
Water providers set deadlines for annual testing. Late testing can lead to reminders, fees or service interruption.
Assuming a new assembly does not need testing
New assemblies are typically tested at installation to confirm proper operation.
Ignoring discharge from an RPZ
Continuous discharge often indicates a problem that should be repaired.
Allowing assemblies to freeze
Outdoor assemblies must be protected or drained before freezing weather to prevent damage.
Losing test records
Keeping copies of test reports helps with future compliance and property sales.
What affects the cost of backflow testing
- Number of assemblies
- Properties with irrigation, fire lines and domestic service may have several assemblies, each tested and reported separately.
- Assembly size and type
- Larger commercial assemblies and RPZs take more time to test than small residential vacuum breakers.
- Access
- Assemblies in vaults, tight mechanical rooms or buried enclosures may need extra time to reach and test safely.
- Repairs
- Rebuild kits and labor for failed assemblies are quoted separately after testing identifies the problem.
Backflow testing questions
- How often do backflow preventers need testing?
- Many water providers require annual testing, but the interval is set by your provider and local code. Your provider's notice will state the deadline.
- Why is my RPZ dripping water?
- An RPZ discharges water from its relief port when it senses a failed check valve or a pressure fluctuation. Occasional discharge during pressure changes can be normal, but steady dripping usually needs service.
- Can a homeowner test their own backflow preventer?
- Generally no. Water providers require testing by a certified backflow tester using calibrated equipment, and only reports from certified testers are accepted.
- Who sends the test report to the water provider?
- Requirements vary. We prepare the report with all required details and can submit it or provide it to you for submission, depending on your provider's process.
- What happens if I skip the test?
- Providers typically issue reminders and follow-up notices. Continued noncompliance can result in fees or, in some areas, water service being suspended until testing is completed.
Get the test done before the notice deadline
Schedule backflow testing and receive a completed report for your water provider.